Posts

Showing posts from January, 2019

Coupling Decoupling Network for Communication Lines

The COUPLING DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL HIGH SPEED COMMUNICATION LINES CDN61000-5C is designed for convenient surge testing with 1.2/50μs pulses, as defined in IEC / EN 61000-4-5 Ed. 3, it works with LISUN SG61000-5 Series Surge Generator. Specification: • Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating volta...

Coupling Decoupling Network for Communication Lines

The COUPLING DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL HIGH SPEED COMMUNICATION LINES CDN61000-5C is designed for convenient surge testing with 1.2/50μs pulses, as defined in IEC / EN 61000-4-5 Ed. 3, it works with LISUN SG61000-5 Series Surge Generator. Specification: • Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating volta...

HCAI-1 High Current Arc Ignition Tester

The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011<Safety of Information Technology Equipment>and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. The HCAI-1 is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors and accessories research, production and QC department. It also suitable used in insolatin...

Costa Rica - Installation and training Integrating Sphere Test System, dustproof and waterproof test equipment, EMI/EMC test machine, etc.

Image
This cuatomer is a large laboratory from Costa Rica. They purchased a set of led test equipment from LISUN this time, including: LPCE-2 High Precision Spectroradiometer Integrating Sphere System , IK07~10 IK Level Tester, JL-34, 56, 78 Waterproof Test , SC-015 Dustproof Testing Machine, LEDLM-80PL LED Optical Aging Test Instrument, ESD61000-2 Electrostatic Discharge Simulator, SG61000-5H12 Surge Generator, etc. There are many equipments and more training content than usual, the installation and training took 4 days. Our engineer communicate in English throughout the process, plus the all-in-English user manual, the customer are very satisfied with our service. Due to the large number of equipment, we just choose several photos of the installation training to share with you here: [caption id="attachment_11430" align="alignnone" width="900"] Figure 1: Group photo in front of LISUN LPCE-2 High Precision Spectroradiometer Integrating Sphere System[/caption] ...

Why should choose a constant current power supply for the LED driver?

Why should choose a constant current power supply for the LED driver? The LED is a light-emitting diode, and its characteristic curve is basically the same as that of a normal diode. When the applied voltage reaches the diode conduction voltage, the slight change of the applied voltage can cause a great change in the diode current. The constant current is used to ensure that the current in the LED is constant. No matter how the voltage changes, the current flowing through the LED does not change, which can ensure the life and light decay of the LED. If a constant voltage source with an output of 12V is used, an electric 16 ohm resistor is connected in series to supply three strings of 0.5W 5630 lamp beads. The lamp voltage is calculated according to 3.3V, the current flowing through the lamp bead Io=(12-3*3.3)/16=0.131A, and the power of a single lamp bead is P=0.131*3.3=0.4323W. Because the temperature of the lamp bead is high The voltage of a single lamp drops to 3V. At this time, th...

Peru - Installation and training for Integrating Sphere Test System

Image
This customer is a relatively large laboratory in Peru, and has purchased a set of LPCE-2 High Precision Spectroradiometer Integrating Sphere System from LISUN recently. They had purchased some other equipment from LISUN before, and are very satisfied with our equipment. So they are willing to place this order from LISUN again this time. More details about LPCE-2 test system, please refer to: https://www.lisungroup.com/product-id-340.html As normal, LISUN engineer visit the customer company to do the installation and training this time. The customer are very satisfaction that we can provide on-site installation and training services. Our engineer is young, professional and have affinity. His service is highly recognized by customer. Looking forward to more cooperations in the near future. Below is photo of the installation and training: [caption id="attachment_11391" align="alignnone" width="900"] Figure 1: Group photo in front of LISUN LPCE-2 High Precis...

DC Electronic Load 2

M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the minor change of voltage and current, so the instrument has a wider application field and achieves better test results. Meanwhile your operation becomes much more comfortable and easy by equipping the high-light VFD, the simple menu and displayed contents and the operation state indicators on all keys. Otherwise the complete and humanized test functions will greatly improve your productivity. The new CR-LED test mode can be a real simulation of LED light features set by the increase in the diode turn-on voltage, fully simulate the working principle of the diode, so that the test voltage and current to achieve a normal and stable value, to avoid the traditional fixed resistor modeunder voltage and current instability or shock, the real reflect the LED drive power load situation. The new series electronic l...

Characteristics of LISUN GDJS series High and Low Temperature Humidity Chamber

Characteristics of LISUN GDJS series High and Low Temperature Humidity Chamber LISUN GDJS series High and Low Temperature Humidity Chamber is according to IEC60068-2-1 (GB/T2423.1) and IEC60068-2-2 (GB/T2423.2). It is used to test the CFL/LED which meets IES LM-80-08 , electricity products, electronic components, material and so on. There is some other manufacturers in China also produce High and Low Temperature Humidity Chamber , and our equipment is mainly different from the following four points: (1) Display temperature: We use Schneider or Omron's relay. And the temperature that can be reached is the temperature under load. But many manufacturers refers to the temperature without load. If under load, the temperature must be different from the original temperature. (2) Water purification device: To generate humidity inside the equipment, there must be distilled water. And there is a water purification device in our High and Low Temperature Humidity Chamber, so we can use tap wa...